Alarm |
Description |
Possible fault |
Action/Machine status |
Reset |
E00 |
No alarm |
E11 |
Difficulty in filling during wash phase |
Tap closed or water pressure insufficient; Drain hose
incorrectly positioned; Water fill solenoid faulty; Leaks
from pressure switch hydraulic circuit; Pressure switch
faulty; Wiring faulty; Circuit board faulty. |
Cycle paused, door closed |
Start |
E13 |
Water leakage |
Drain hose incorrectly positioned; Water pressure
insufficient; Water fill solenoid faulty; Leaks or blockage
in
pressure switch hydraulic circuit; Pressure switch faulty;
Circuit board faulty. |
Cycle paused, door closed |
Start |
E21 |
Difficulties in draining |
Drain hose kinked/blocked/incorrectly positioned; Drain
filter
clogged or dirty; Drain pump faulty; Pressure switch faulty;
Wiring faulty; Circuit board faulty; Current leakage from
heating element to ground. |
Cycle paused |
Start |
E23 |
Drain pump triac faulty |
Drain pump faulty; Wiring faulty; Circuit board faulty. |
Safety drain - Cycle stopped, door open |
Selector on “0” |
E24 |
Problems with «sensing» of drain pump triac |
Circuit board faulty. |
Safety drain – Cycle stopped, door released |
Selector on “0” |
E33 |
Incongruence between contact closure of anti-
boiling and 1st level of pressure switch |
Pressure switch faulty; Current leakage from heating
element to ground; Heating element; Wiring faulty; Circuit
board faulty. |
Safety drain - Cycle stopped, door open |
Selector on “0” |
E35 |
Water overflow |
Water fill solenoid faulty; Leaks from pressure switch
hydraulic circuit; Pressure switch faulty; Wiring faulty;
Circuit
board faulty. |
Cycle blocked, door closed. Safety drain.
Drain pump (sequence 5 min. ON - 5 min.
OFF) |
Selector on “0” |
E36 |
«sensing» circuit of anti-boiling pressure switch
faulty |
Circuit board faulty. |
Cycle blocked, door closed |
Selector on “0” |
E37 |
«sensing» circuit of 1st level faulty |
Circuit board faulty. |
Cycle blocked, door closed |
Selector on “0” |
E39 |
HV «sensing» circuit of anti-flooding pressure
switch faulty |
Circuit board faulty. |
Cycle blocked, door closed |
Selector on “0” |
E41 |
Door open |
Door safety interlock faulty; Wiring faulty;
Circuit board faulty. |
Cycle paused |
Start |
E42 |
Problems with aperture of door |
Door safety interlock faulty; Wiring faulty;
Circuit board faulty |
Cycle paused |
Start or Selector
on “0” |
E43 |
Power triac on door interlock faulty |
Door safety interlock faulty; Wiring faulty;
Circuit board faulty. |
Safety drain, door released |
Selector on “0” |
E44 |
Door interlock «sensing» faulty |
Circuit board faulty. |
Safety drain, door released |
Selector on “0” |
E45 |
«sensing» on door interlock triac faulty |
Circuit board faulty. |
Safety drain, door released |
Selector on “0” |
E51 |
Motor power triac short-circuited |
Circuit board faulty;
Current leakage from motor or wiring. |
Cycle blocked, door closed (after 5 attempts in diagnostics
or immediate during selection) |
Selector on “0” |
E52 |
No signal from motor tachimetric generator |
Motor faulty; Wiring faulty;
Circuit board faulty. |
Cycle blocked, door closed (after 5 attempts in diagnostics
or immediate during selection) |
Selector on “0” |
E53 |
«sensing» circuit on motor triac faulty |
Circuit board faulty. |
Cycle blocked |
Selector on “0” |