Privileg washing machine wiring diagram service manual error code circuit schematic schema repair instruction guide user manual free pdf download

 

       
       
       
       

 

 

                                                          Search and download service manual

   
   
   

Washing machine circuit diagram EWM1000plus EWM2000evo EWM3000new platform

 

Components in the appliance Components of the PCB
  1. Electronic board
2. Suppressor
3. ON/OFF switch
4. ON/OFF pilot lamp
5. Door interlock
6. Anti-boiling pressure switch
7. Heating element
8. 1st level pressure switch
9. Anti-overflow pressure switch (not all models)
10. Pre-wash solenoid valve
11. Wash solenoid valve
12. Bleach solenoid valve
(not all models)
13. Drain pump
14. Closed door lamp
(not all models)
15. Control/display board
16. Thermal cut-out (motor)
17. Stator (motor)
18. Rotor (motor)
19. Tachometric generator (motor)
20. NTC temperature sensor
BELV_TY Bleach solenoid Triac
DOOR_TY Door interlock Triac
DRAIN_TY Drain pump Triac
K1 Heating element relay
K2 Motor relay: clockwise rotation
K3 Motor relay: anti-clockwise rotation
K4 Motor relay: half field power supply (models with higher spin at
1200 rpm)

MOTOR_TY Motor Triac
PWELW_TY Pre-wash solenoid Triac
Serial interface Asynchronous serial interface
WELV_TY Wash solenoid Triac

 

 

 

Components in the appliance Components of the PCB
1. Electronic board
2. Suppressor
3. Drain pump
4. Aqua control
5. Anti-boiling pressure switch
6. Door interlock
7. Heating element
8. 1st level pressure switch
9. Anti-overflow pressure switch (not all models)
10. Pre-wash solenoid valve
11. Wash solenoid valve
12. Bleach solenoid valve
(not all models)
13. Closed door lamp (not all models)
14. Selector
15. Control/display board
16. Thermal cut-out (motor)
17. Stator (motor)
18. Rotor (motor)
19. Tachometric generator (motor)
20. NTC temperature sensor
BELV_TY Bleach solenoid Triac
DOOR_TY Door interlock Triac
DRAIN_TY Drain pump Triac
K1 Heating element relay
K2 Motor relay: clockwise rotation
K3 Motor relay: anti-clockwise rotation
K4 Motor relay: half field power supply (models with higher spin at
1200 rpm)

MOTOR_TY Motor Triac
PWELW_TY Pre-wash solenoid Triac
Serial interface Asynchronous serial interface
WELV_TY Wash solenoid Triac

 

 

Burning on the circuit control board EWM1000plus platform

In case of burning on the main circuit board, check that the problem is not caused by another electrical component (short-circuits, poor insulation, water leakage). Refer to the figures below in order to identify the component that might have caused the burning according to the position of the burned area. The circuit board shown below is the version with the greatest number of components: other boards may not feature all these components.

Burning on the circuit control board EWM1000plus platform washing machine

 

 

Connectors on circuit control board EWM1000plus platform

Connectors on circuit control board EWM1000plus platform washing machine

J1 J2 J3 J4
Motor
J1-1 Motor (triac)
J1-2 Motor (rotor)
J1-3 Motor (rotor)
J1-4 Motor (stator - full range)
J1-5 Motor (stator - 1/2 range)
Door lamp
J2-1 Door lamp
J2-2 Door lamp
J3-1 Door safety interlock
(line-sensing)
J3-2 Drain pump (line)
J3-3 Aqua Control (line)
J3-4 Anti-overflow pressure
switch (line)
J3-5 1st level (sensing)
J3-6 Anti-overflow (sensing)
J3-7 Drain pump (triac)
Solenoid valves
J4-1 Prewash solenoid
(line)

J4-2 Bleach solenoid (line)
J4-3 Prewash solenoid (triac)
J4-4 Wash solenoid (triac)
J4-5 Bleach solenoid (triac)
J5 J6 J7 J8
J5-1 Drum positioning (DSP)
(sensing)
J5-2 Drum positioning (DSP)
(+5v)
J5-3 Tachometric generator
motor
J5-4 Tachometric generator
motor
J5-5 NTC temperature sensor
washing (sensing)
J5-6 NTC temperature sensor
washing (+5v)
Heating element:
J6-1 Relay
J6-2 Line
DAAS Interface:
J7-1 ASY_IN
J7-2 ASY_OUT
J7-3 Vcc (+5v)
J7-4 GND
Display board
J8-1 Vcc (+5v)
J8-2 GND
J8-3 SY OUT
J8-4 SY IN
J8-5 SY CLK
J10 J12 J14  
J10-1 Line ON/OFF
J10-2 Door safety interlock
(triac)
J10-3 Washing solenoid
(line)
J12-1 LV2 (sensing)
J12-2 Door safety interlock
Flowmeter
J14-1 GND
J14-2 Vcc (5v)
J14-3 Flowmeter_dgt_in
J14-4 Flowmeter_anl_in
 

 

 

Reading the alarm codes  
In order to read the last alarm code memorized in the EEPROM on the PCB:
with knob
Enter diagnostics mode
Irrespective of the type of PCB and configuration, turn the
programme selector
clockwise to the tenth position.
without knob
Press the Fabrics (1) or Temperature (2) button until LED L10
lights.
 
 

Displaying the alarm

 

 
The alarm is displayed by a repeated flashing sequence of the two LEDs (0.4
seconds lit, 0.4 seconds off, with an interval of 2.5 seconds between sequences).
The buzzer (if featured) will sound “bips” in synchronization with the flashing of
the LEDs
.
END OF CYCLE LED indicates the first digit of the alarm code (family)
START/PAUSE indicates the second digit of the alarm code (number
within the family)
These two LEDs are featured on all models (though they are
configured
differently
), and flash simultaneously.
Notes:
The first letter of the alarm code “E” (Error) is not displayed, since this letter is
common to all alarm codes.
The alarm code “families” are shown in hexadecimal; in other words:
A is represented by 10 flashes
B is represented by 11 flashes
...
F is represented by 15 flashes
Configuration errors are shown by the flashing of a series of LEDs.
 

Examples of alarm displays

 

 
Example: Alarm E43 will display the following:
On the display, if featured, E43
The sequence of four flashes of the End-of-cycle LED indicates the first number E43;
The sequence of three flashes of the Start/Pause LED indicates the second number E43;

 

Alarm Description Possible malfunction Action/status of machine Reset
E00 No alarm ---
E11 Poor water fill before wash cycle Tap closed or water pressure too low; Drain tube improperly positioned;
Water fill solenoid valve is defective; Leaks from water circuit on
pressure switch; Pressure switch defective; Wiring defective; Main board
defective.
Cycle is paused with door locked Start
E12 Difficulty in water fill during drying (maximum
time 3 min. water fill in drying during the wash
load unrolling phase)
Tap closed or water pressure too low; solenoid valve; pressure switch
water circuit; pressure switches; wiring; main board.
Cycle is paused Start
E13 Water leaks Drain tube improperly positioned; Water pressure too low;
Water fill solenoid valve is defective; Water circuit on pressure switch is
leaking/clogged; Pressure switch defective.
Cycle is paused with door locked Start
E21 Poor draining Drain tube kinked/clogged/improperly positioned; Drain filter
clogged/dirty; Drain pump defective; Pressure switch defective; Wiring
defective; Main board defective; Electrical current leak between heating
element and ground.
Cycle is paused Start
E22 Difficulty in water fill during drying or drying
condenser clogged (anti-boiling pressure
switch closed on “FULL”)
Drain hose kinked; filter clogged: drying condenser clogged; drain pump
faulty; pressure switches faulty; wiring; main circuit board defective;
current leakage between heater and ground.
Cycle is paused Start
E23 Defective triac for drain pump Drain pump defective; Wiring defective; Main board defective. Emergency drain procedure - Cycle
stops with door unlocked
OFF/reset
E24 Malfunction in sensing circuit on triac for drain
pump
Main board defective. Emergency drain procedure - Cycle
stops with door unlocked
OFF/reset
E31 Malfunction in pressure switch circuit
(frequency of signal from pressure switch out
of limits)
Pressure switch; Wiring; Main board; Cycle stops with door locked OFF/reset
E32 Electronic pressure switch improperly
calibrated (level on electronic pressure switch
differs from 0-66 mm after initial calibration
drain and when antiboiling pressure switch is
on “empty”).
Tap is closed or water pressure is too low;
Solenoid valve;
Water circuit on pressure switches; pressure switches;
Wiring; main board;
Cycle is paused Start
E33 Inconsistency between level on electronic
pressure switch and level on antiboiling
pressure switch 1-2 (fault persists for at least
60 sec.).
Pressure switch defective;
Electrical current leak between heating element and ground; Heating
element; Wiring defective;
Main board defective.
Water circuit;
Emergency drain procedure - Cycle
stops with door unlocked
OFF/reset
E34 Inconsistency between level on electronic
pressure switch and level on antiboiling
pressure switch 2 (fault persists for at least 60
sec.).
Pressure switch defective;
Electrical current leak between heating element and ground; Heating
element; Wiring defective;
Main board defective.
Water circuit;
Emergency drain procedure - Cycle
stops with door unlocked
OFF/reset
E35 Overflow Water fill solenoid valve is defective; Leaks from water circuit on
pressure switch; Pressure switch defective; Wiring defective; Main board
defective.
Cycle stops. Emergency drain
procedure. Drain pump continues to
operate (5 min. on, then 5 min. off, etc.).
OFF/reset
E36 Sensing circuit on antiboiling pressure switch
1 defective
Main board defective.
Electrical current leak between drying heating element and ground
Cycle stops with door locked OFF/reset
E37 1st level sensing circuit faulty PCB faulty. Cycle blocked, door locked. OFF/reset
E38 Pressure chamber blocked
(water level does not vary for at least 30 sec.
during drum rotation
Pressure switch hydraulic circuit;
Pressure switches;
Motor drive belt broken;
Heating phase skipped. ---
E39 “HV” sensor of anti-overflow level faulty PCB faulty. Cycle blocked, door locked. OFF/reset
E3A Heating elem. relay sensing faulty PCB faulty. Cycle blocked, door locked OFF/reset
E41 Door open Door interlock faulty; wiring faulty;
PCB faulty.
Cycle paused Start
E42 Problems of door closure Door interlock faulty; wiring faulty;
PCB faulty.
Cycle paused Start
E43 Interlock power supply triac faulty Door interlock faulty; wiring faulty;
PCB faulty.
(Safety drain cycle) Cycle blocked OFF
E44 Door interlock sensor faulty PCB faulty. (Safety drain cycle) Cycle blocked OFF
E45 Door interlock sensing circuit triac faulty PCB faulty (Safety drain cycle) Cycle blocked OFF
E51 Motor power supply triac short-circuited PCB faulty; current leakage from motor or from wiring. Cycle blocked, door locked (after 5
attempts)
OFF/reset
E52 No signal from motor tachometric generator Motor faulty; wiring faulty; PCB faulty Cycle blocked, door locked (after 5
attempts)
OFF/reset
E53 Motor triac sensing circuit faulty PCB faulty. Cycle blocked, door locked OFF/reset
E54 Motor relay contacts sticking PCB faulty; current leakage from motor or from wiring Cycle blocked, door locked (after 5
attempts)
OFF/reset
E57 Inverter is drawing too much current (>15A) Motor defective; Wiring defective on inverter for motor, inverter board
defective.
Cycle stops with door locked (after 5
attempts).
OFF/reset
E58 Motor is drawing too much current (>4.5A) Motor defective; Wiring defective on inverter for motor, inverter board
defective, abnormal motor operation (motor overloaded).
Cycle stops with door locked (after 5
attempts).
OFF/reset
E59 No signal from tachometric generator for more
than 3 seconds
Motor defective; Wiring defective on inverter for motor;
Inverter board defective.
Cycle stops with door locked (after 5
attempts).
OFF/reset
E5A Overheating on heat dissipater for inverter Inverter board defective. NTC open (on the inverter board).
Overheating caused by continuous operation or ambient conditions (let
appliance cool down)
Cycle stops with door locked (after 5
attempts).
OFF/reset
E5B Input voltage is lower than 175V Wiring defective, Inverter board defective Cycle stops with door locked (after 5
attempts).
OFF/reset
E5C Input voltage is too high Inverter board defective, the mains voltage is too high (measure the
mains voltage)
Cycle stops with door locked (after 5
attempts).
OFF/reset
E5D Data transfer error between inverter and main
board
Line interference, Wiring defective, defective main board or inverter
board
Cycle stops with door locked (after 5
attempts).
OFF/reset
E5E Communication error between inverter and
main board
Defective wiring between main board and inverter board,
Defective inverter board, defective main board
Cycle stops OFF
E5F Inverter board fails to start the motor Defective inverter board, Defective wiring, defective main board Cycle stops with door locked (after 5
attempts).
OFF/reset
E61 Insufficient heating during wash cycle Defective NTC sensor for wash cycle; Heating element defective; Wiring
defective; Main board defective.
Heating phase is skipped Start
E62 Overheating during wash cycle Defective NTC sensor for wash cycle; Heating element defective; Wiring
defective; Main board defective.
Safety drain cycle - Cycle stops with door
unlocked
OFF/reset
E66 Relay supplying power to heating element
defective
Main board defective; Electrical current leak from heating element to
ground.
Safety drain cycle - Cycle stops with door
unlocked
OFF/reset
E71 NTC sensor for wash cycle defective Defective NTC sensor; Wiring defective;
Main board defective.
Heating is skipped Start
E72 Fault in NTC sensor on drying condenser
(voltage out of range = short-circuit, open
circuit)
Drying NTC sensor (condenser) defective; wiring defective; main circuit
board defective.
Heating is skipped Start
E73 Fault in NTC sensor on drying duct (voltage
out of range = short-circuit, open circuit)
Drying NTC sensor (duct) defective; wiring defective; main circuit board
defective.
Heating is skipped Start
E74 NTC sensor for wash cycle improperly
positioned
NTC sensor improperly positioned; Defective NTC sensor; Wiring
defective; Main board defective.
Heating is skipped Start
E82 Error in selector reset position PCB faulty (Wrong configuration data). Selector, wiring --- OFF/reset
E83 Error in reading selector PCB faulty (Wrong configuration data). Selector, wiring Cycle cancelled ---
E84 Recirculation pump defective (inconsistency
between the state of the sensing circuit for the
recirculation pump and the state of the triac)
Recirculation pump;
Wiring;
Main board;
Machine drains and cycle stops (with
door unlocked)
OFF/reset
E85 Defective sensing circuit on triac for
recirculation pump (input voltage on
microprocessor remains at 0 or 5 V).
Main board Machine drains and cycle stops (with
door unlocked)
OFF/reset
E91 Communication error between main board and
display board
Wiring defective; Control/display board defective
Main board defective.
Cycle stops ---
E92 Inconsistency in communication between main
board and display board
(versions not compatible)
Wrong control/display board;
Wrong main board (not right for model).
Cycle stops ---
E93 Configuration error on appliance Main board defective (Improper programming). Cycle stops OFF/reset
E94 Configuration error on wash cycle Main board defective (Improper programming). Cycle stops OFF/reset
E95 Communication error between microprocessor
and EEPROM
Main board defective. Cycle stops OFF/reset
E97 Inconsistency between list of programmes and
configuration of cycle
Main board defective (Improper programming). Cycle stops OFF/reset
E98 Communication error between microprocessor
and clock
Display board faulty The cycle continues -----------
EB1 Frequency of power supplied to appliance out
of limits
Problems with the power mains (wrong power/interference); Main board
defective.
Cycle stops ---
EB2 Input voltage too high Problems with the power mains (wrong power/interference); Main board
defective.
Cycle stops ---
EB3 Input voltage too low Problems with the power mains (wrong power/interference); Main board
defective.
Cycle stops ---
EBE Inconsistency between safety relay and
sensing circuit
Main board defective, defective wiring Machine drains and cycle stops (with
door unlocked)
OFF/reset
EBF Sensing circuit on safety system defective
(input voltage on microprocessor remains at 0
or 5 V).
Main board defective Machine drains and cycle stops (with
door unlocked)
OFF/reset
EC1 Solenoid valve inoperative but flow meter
operating
Main board defective, Solenoid valve defective Cycle stops with door locked (after 5
attempts).
OFF/reset
EC2 Signal from turbidity sensor out of limits Turbidity sensor defective, Main board defective, Wiring defective ----------------------- Start/reset
EC3 Signal from weight sensor out of limits Weight sensor defective, Main board defective, Wiring defective --- Start/reset
EF1 Drain filter clogged
(drain cycle too long)
Drain tube clogged/kinked/placed too high;
Drain filter dirty/clogged.
Warning is displayed at end of cycle
(relative LED is lit)
---
EF2 Too much detergent
(too much foam during drain cycles)
Too much detergent used; Drain tube clogged/kinked;
Drain filter dirty/clogged.
Warning is displayed at end of cycle
(relative LED is lit)
---
EF3 “Water Control” system tripped Water leaks onto base frame; water control system defective. Machine drains and cycle stops OFF/reset
EF4 Water fill pressure too low, no signal from flow
meter and solenoid valve is open
Tap closed, water pressure too low --------------------------- Reset

 

 

PNC_ELC

Platform

Pub

Model

BrandName

ProdDate

91451728300

EWM1000plus

599367197

025894_20305

Privileg

20041105

91451730200

EWM1000plus

599368370

029055_20331

Privileg

20050128

91451747400

EWM1000plus

599379656

072349_20682

Privileg

20060526

91451724300

EWM1000plus

599363779

118907_20263

Privileg

20040402

91451724301

EWM1000plus

599374974

118907_20263

Privileg

20051230

91451744900

EWM1000plus

599377487

118907_20567

Privileg

20060407

91476050200

EWM1000plus

599367523

126006_20309

Privileg

20041126

91490120400

EWM1000plus

599380686

126006_20533

Privileg

20060623

91490121000

EWM1000plus

599380703

126006_20736

Privileg

20060630

91490121002

EWM1000plus

599701997

126006_20736

Privileg

20070727

91490121003

EWM1000plus

599701793

126006_20736

Privileg

20070730

91490121100

EWM1000plus

599704061

126006_20984

Privileg

20071109

91451522400

EWM1000plus

599369610

141799_20340

Privileg

20050325

91452114300

EWM1000plus

599382633

145386_20776

Privileg

20060915

91452114301

EWM1000plus

599702192

145386_20776

Privileg

20071005

91451706000

EWM1000plus

599368132

156647_20326

Privileg

20050107

91451733100

EWM1000plus

599370815

181507_20358

Privileg

20050516

91452112200

EWM1000plus

599381100

222714_20697

Privileg

20060630

91452112201

EWM1000plus

599386886

222714_20697

Privileg

20070326

91452211300

EWM1000plus

599381480

224579_20700

Privileg

20060713

91451745300

EWM1000plus

599374118

232515_20458

Privileg

20051202

91451522300

EWM1000plus

599369609

237296_20339

Privileg

20050325

91451524500

EWM1000plus

599382723

237296_20568

Privileg

20060526

91451721200

EWM1000plus

599361869

238549_20231

Privileg

20031128

91452114500

EWM1000plus

599383570

247084_20805

Privileg

20061013

91452114501

EWM1000plus

599386891

247084_20805

Privileg

20070326

91452114600

EWM1000plus

599383571

247101_20806

Privileg

20061013

91452114601

EWM1000plus

599388659

247101_20806

Privileg

20070511

91452112100

EWM1000plus

599381098

282129_20778

Privileg

20060630

91451726300

EWM1000plus

599366374

289046 _20291

Privileg

20040917

91451746900

EWM1000plus

599378997

312292_20665

Privileg

20060505

91451746700

EWM1000plus

599376351

316134_20668

Privileg

20060303

91451728200

EWM1000plus

599367447

340593_20307

Privileg

20041119

91451728201

EWM1000plus

599374965

340593_20307

Privileg

20060106

91451738500

EWM1000plus

599374253

340593_20307

Privileg

20051216

91451726000

EWM1000plus

599364974

360614_20287

Privileg

20040625

91451722500

EWM1000plus

599362608

382523_20259

Privileg

20040206

91451722501

EWM1000plus

599374973

382523_20259

Privileg

20051230

91451733500

EWM1000plus

599370836

390368_20377

Privileg

20050520

91451733501

EWM1000plus

599375001

390368_20377

Privileg

20060106

91451738600

EWM1000plus

599375243

390368_20513

Privileg

20060120

91451733200

EWM1000plus

599370816

424747_20359

Privileg

20050516

91451704000

EWM1000plus

599364412

435555_20266

Privileg

20040521

91451705600

EWM1000plus

599367442

447022_20308

Privileg

20041119

91452111600

EWM1000plus

599381781

460514_20740

Privileg

20060728

91452111601

EWM1000plus

599386885

460514_20740

Privileg

20070326

91452112700

EWM1000plus

599381387

460640_20695

Privileg

20060714

91452112701

EWM1000plus

599388655

460640_20695

Privileg

20070511

91475651200

EWM1000plus

599365211

477164_20271

Privileg

20040702

91475651201

EWM1000plus

599373865

477164_20271

Privileg

20051111

91475654200

EWM1000plus

599374416

477164_20271

Privileg

20051216

91451521500

EWM1000plus

599367386

503663_20310

Privileg

20041119

91452111900

EWM1000plus

599381484

504456_20698

Privileg

20060714

91451746800

EWM1000plus

599376349

546750_20441

Privileg

20060303

91451725100

EWM1000plus

599364405

577808_20264

Privileg

20040521

91451726200

EWM1000plus

599366346

597085_20290

Privileg

20040917

91451721400

EWM1000plus

599361874

604382_20233

Privileg

20031128

91452112000

EWM1000plus

599381097

610636_20699

Privileg

20060630

91451725200

EWM1000plus

599364408

628649_20265

Privileg

20040521

91452114901

EWM1000plus

599387341

694479_20824

Privileg

20070316

91451711500

EWM1000plus

599379457

695864_20666

Privileg

20060519

91451745200

EWM1000plus

599374117

724401_20457

Privileg

20051202

91452112500

EWM1000plus

599381286

732075_20693

Privileg

20060714

91452112501

EWM1000plus

599386884

732075_20693

Privileg

20070326

91452115001

EWM1000plus

599387884

732613_20825

Privileg

20070406

91452114800

EWM1000plus

599384247

746699_20733

Privileg

20061103

91452115400

EWM1000plus

599385142

746699_20733

Privileg

20061208

91451733300

EWM1000plus

599372016

762327_20380

Privileg

20050715

91451707200

EWM1000plus

599371431

765348_20393

Privileg

20050624

91451708300

EWM1000plus

599375241

765348_20515

Privileg

20060120

91451521600

EWM1000plus

599367388

767644_20311

Privileg

20041119

91451521700

EWM1000plus

599367391

775542_20312

Privileg

20041119

91451728100

EWM1000plus

599367444

775600_20306

Privileg

20041119

91451728101

EWM1000plus

599374964

775600_20306

Privileg

20060106

91451738400

EWM1000plus

599374255

775600_20306

Privileg

20051216

91451730100

EWM1000plus

599368134

799243_20325

Privileg

20050107

91475651300

EWM1000plus

599365213

805251_20272

Privileg

20040702

91475651301

EWM1000plus

599373866

805251_20272

Privileg

20051111

91475654300

EWM1000plus

599374409

805251_20272

Privileg

20051216

91475656700

EWM1000plus

599381143

805251_20982

Privileg

20060707

91475657300

EWM1000plus

599703824

805251_20982

Privileg

20071109

91452114400

EWM1000plus

599382885

833658_20775

Privileg

20060929

91452114401

EWM1000plus

599386890

833658_20775

Privileg

20070326

91451746600

EWM1000plus

599376346

879436_20667

Privileg

20060303

91451721300

EWM1000plus

599361872

914345_20232

Privileg

20031128

91451746400

EWM1000plus

599375429

919470_20456

Privileg

20060203

91475651400

EWM1000plus

599365262

926084_20285

Privileg

20040709

91475651401

EWM1000plus

599373822

926084_20285

Privileg

20051111

91475654400

EWM1000plus

599374469

926084_20536

Privileg

20051223

91475656800

EWM1000plus

599382450

926084_20983

Privileg

20060901

91475657400

EWM1000plus

599704416

926084_20983

Privileg

20071123

91452112600

EWM1000plus

599381386

928643_20694

Privileg

20060714

91452112601

EWM1000plus

599386888

928643_20694

Privileg

20070326

91451733000

EWM1000plus

599370827

946137_20356

Privileg

20050520

91451733001

EWM1000plus

599374970

946137_20356

Privileg

20060106

91451738300

EWM1000plus

599374430

946137_20356

Privileg

20051216

91451732900

EWM1000plus

599371436

970068_20355

Privileg

20050624

91451732901

EWM1000plus

599374966

970068_20355

Privileg

20060106

91451738200

EWM1000plus

599374439

970068_20355

Privileg

20051216

91451733600

EWM1000plus

599370837

971534_20378

Privileg

20050520

91451733601

EWM1000plus

599375003

971534_20378

Privileg

20060106

91451738700

EWM1000plus

599375244

971534_20514

Privileg

20060120

91451732800

EWM1000plus

599371434

980545_20354

Privileg

20050624

91451732801

EWM1000plus

599374968

980545_20354

Privileg

20060106

91451738100

EWM1000plus

599374438

980545_20354

Privileg

20051216

91451631900

EWM2000evo

599365347

179947_20268

Privileg

20040716

91451090100

EWM2000evo

599372167

324885_20357

Privileg

20050722

91451091700

EWM2000evo

599375229

324885_20539

Privileg

20060120

91451632000

EWM2000evo

599365410

657648_20269

Privileg

20040716

91460112300

EWM2000evo

599375239

758765_20544

Privileg

20060120

91451638300

EWM2000evo

599379574

767684_20685

Privileg

20060526

91460167100

EWM2000evo

599375316

782160_20546

Privileg

20060120

91460167000

EWM2000evo

599375315

954713_20545

Privileg

20060120

91451752800

EWM3000new

599365432

233629_20270

Privileg

20040716

91490007900

EWM3000new

599383370

543976_20701

Privileg

20061007

91452330200

EWM3000new

599701925

679310_20934

Privileg

20070921

 

 

 

 

     
    Privileg washing machine schematic diagram error codes fault service manual circuit diagram wiring schema repair instruction guide user manual free pdf download. Privileg Service Handbuch Schaltungen Reparaturanleitung Bedienungsanleitungen kostenlos pdf download. Privileg Schéma service manual schéma zapojení schémat oprava návod k obsluze návod k použití free pdf ke stažení. Privileg Schéma de principe de service manuel Schéma câblage schéma réparation instruction notice manuel téléchargement gratuit pdf. Privileg Diagrama esquemático serviço manual do circuito diagrama de fiação esquema reparação instrução guia manual do usuário livre PDF Download. Privileg Schema di servizio manuale circuito schema elettrico schema di riparazione di istruzioni guida manuale pdf gratuito scaricare. Privileg schemat instrukcja obsługi Schemat okablowania Schemat naprawa instrukcja instrukcja obsługi free pdf pobierz. Privileg şeması servis manuel devre şeması kablolama şeması onarım talimat kılavuzu kullanım kılavuzu ücretsiz pdf indir. Privileg Schema service manual schema bedrading schema reparatie gebruiksaanwijzing handleiding gratis pdf te downloaden. Privileg schematică diagrame de service manualul de circuit diagrama de conexiuni Schema de reparatii de instructiuni Manual de utilizare pe gratis download pdf.  
     
 

1. PURPOSE OF THIS SERVICE MANUAL

The purpose of this Service Manual is to provide Service Engineers, who already have the basic knowledge necessary to repair household washing machines, with information of a general nature regarding the HEC range of washing machines.

More detailed information regarding specific models may be found in the Service Notes and Service

Manuals (issued separately) for each specific model or functionality.

This information covers:

  • Circuit diagrams

  • Exploded views of spare parts

  • Spare parts lists

  • Functions and diagnostics

2. IMPORTANT NOTES

  • Repairs to electrical appliances must be effected only by qualified personnel.

  • Before accessing the components inside the appliance, always remove the plug from the power socket.

  • Where possible, ohmic measurements should be effected rather than direct measurement of voltage and current.

  • Certain metal components inside the appliance may have sharp edges. Care should be taken to avoid cuts or abrasions.

  • Before laying the appliance on the floor, always drain any water by means of the system placed beside the drain filter.

  • Never lay the appliance on its right side (i.e. electronic control unit side); this would cause the water in the detergent dispenser to fall onto electrical components, thus damaging them.

  • After repairing the appliance, always perform the final tests.
3. CAUTION:
  • Before servicing receivers covered by this service manual and its supplements and addenda, read and follow the SAFETY PRECAUTIONS of this publication. Remember: Safety First.
  • General Guidance An isolation Transformer should always be used during the servicing of a receiver whose chassis is not isolated from the AC power line.
  • Use a transformer of adequate power rating as this protects the technician from accidents resulting in personal injury from electrical shocks. It will also protect the receiver and it's components from being damaged by accidental shorts of the circuitry that may be inadvertently introduced during the service operation.

 

 

 

 

 
Copyright © 2007 Tehnomagazin.com
Terms & Conditions                                        Privacy Policy                                                Impressum