Model: AE2, AE2A, AE2B, AE2F, KV-A2131A, ...
Subject: SET GOES OFF AFTER A WHILE, OR LED BLINKS 13 X WHE
Symptom: Set goes off after a while, or set start
blinking 13 times when you start the set.
Cause: Set has bad contacts on IC1501 or this IC1501 is
already defekt due to a bad contacts.
Remedy: Change IC1501 and check his fusible resistors
R854 a
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: NO POWER, + B IS TOO HIGH (170V)
Symptom: TV doesn't start. +B is too high (170 V) Only
demagnetisation is clicking.
Cause: PS601 is open due to bad contacts at IC 681
Remedy: Change PS601 and resolder IC681, R681.
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: PLOP NOISE, AFTER A WHILE NO SOUND.(IC251,IC261,R6
Symptom: Plop-noise
Cause: One of the audio amplifiers is defekt.(TDA 2052)
Check also the value of R627 (27ohm)
Remedy: Change the audio amplifiers and change R 627.
References of the TDA 2052 depends of the exact
Model:. Check service manual p
Model: AE2, KV-B2511A, KV-B2511B, KV-B2511D, KV-B2511K,
...
Subject: INTERMITTENT NO COLOUR.(FS057)
Symptom: Intermittenly no colour
Cause: Bad contact FS057
Remedy: Resoldering FS057
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: NO POWER, +B TENSION LOWERS FROM 135V TO
60V.(Q281
Symptom: TV doesn't start up. +B tension goes from 135V
to 60V.(stand-by tension)
Cause: Q 281, Q 282 are defekt.(protection circuit
audio)
Remedy: Change Q281,Q282
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: PICTURE BECOMES REDDISH, BLUEISH OR GREENISH AND
Symptom: Picture becomes reddish, blueish or greenish
and blanks. Led blinks constantly.
Cause: The collectors of the RGB transistors (BF 871)
are touching because of dust or other cause.
Remedy: Reposition the 6 transistors and resolder them
corr
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: NO POWER.(R610)
Symptom: No power
Cause: Q601, F651, IC601 are defekt, and even when they
are replaced the power supply brakes immediatly.
Remedy: Check R610 = 120K
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: SET GOES INTO PROTECTION AND BLINKS 8
TIMES.(IC684
Symptom: Set goes in protection and blinks 8 times (AV
switch)
Cause: Bad contact at IC 684 (9V stabilisator)
Remedy: Resoldering IC 684
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: NO POWER.(PS682)
Symptom: No power
Cause: PS682 is open
Remedy: Change PS682 Attention: In some SM you won't
find PS682
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: NO POWER.(R612)
Symptom: No power
Cause: R 612 is open
Remedy: Change R 612= 430Mohm
Model: AE2, KV-B2511A, KV-B2511B, KV-B2511D, KV-B2511K,
...
Subject: THE SET GOES ON AN OFF AND LED BLINKS 11
TIMES.(IC
Symptom: Set goes on and off and blanks 11X
Cause: IC01 is defekt (SDA5248CI)
Remedy: Change this IC
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: LED BLINKS 7 TIMES.(IC 561)
Symptom: After soldering the IC501 (vertical amplifier)
it is possible that image is still unstabel. 7 times blinking is possible
Cause: IC 561 is unstabel when warming up. (geometry
processor)
Remedy: Change IC 561
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: RED,BLUE OR GREEN RETRACE LINES IN
PICTURE.(Q707,Q
Symptom: Red, blue or green image with retrace lines in
the picture
Cause: In most of the cases one of the 2SA1091 is
leaking.
Remedy: Change these 3 transistors Q 707, Q708, Q709
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: PLOP NOISE.(IC201)
Symptom: Plop noise
Cause: TDA 6612 is defekt.
Remedy: Change this ic
Model: AE2, KV-B2511A, KV-B2511B, KV-B2511D, KV-B2511K,
...
Subject: NO NICAM SOUND.(IFB101)
Symptom: No NICAM sound
Cause: IFB 101 is defekt due to a bad SIF signal.
Remedy: Change IFB 101
Model: AE2, AE2B, AEA
Subject: PICTURE IS GREEN AND YELLOW.(IC302)
Symptom: The picture is green and yellow
Cause: The electronic delay line is defekt.
Remedy: Change TDA 4660 It is possible you get a
replacement for this ic
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: SET GIVES DIFFERENT ERROR CODES.(Q611,Q612,
R640,R
Symptom: Set gives different error codes (Led blinks 3
times, afterwards 13 times)
Cause: Protection circuit is defekt ( Q611 and Q612) and
activates the X-ray protection
Remedy: Change these 2 transistors Other components in
this circuitry can
Model: AE2, KV-B2511A, KV-B2511B, KV-B2511D, KV-B2511K,
...
Subject: BAD FOCUS IN THE MIDDLE OF THE SCREEN (IC1603)
Symptom: Bad focus in the middle of the screen
Cause: LM 393 is defect.
Remedy: Change this ic. This is only for
Model:s with a dynamic focus.
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: NO COLOUR , MENU AND OSD ARE UNSTABEL.(IC681)
Symptom: No colour and menu and OSD are unstabel
Cause: IC 681 gives wrong output voltages Normally 5V
and 12V
Remedy: Change IC 681
Model: AE2, KV-B2511A, KV-B2511B, KV-B2511D, KV-B2511K,
...
Subject: NO POWER.(Q801)
Symptom: No power
Cause: Q801 is short, due to the +B tension = 190V.
Remedy: Check and change if neccesary IC603, D616,
IC602.
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: PLOP NOISE.(R627)
Symptom: Plop- noise
Cause: R 627 = open.
Remedy: Replace this resitor and check all audio
amplifiers. One of them should be defect.(surround amplifier !!!!!)
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: SET SOMETIMES IN PROTECTION.(Q611,Q610)
Symptom: Set goes in protection (intermittent.)
Cause: Q 610 or Q 611 are leaking.
Remedy: Change both transistors. Because if one or both
transistors are leaking the X- ray protection gets activated.
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: CYCLIC POWER ON/OFF.(PS601)
Symptom: No power(cycling power on/off.)
Cause: PS601 is open.
Remedy: Replace this fuse.
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: SYNC PROBLEM.(IC681)
Symptom: Sync problem
Cause: IC 681 is defect.
Remedy: Change this ic. Sometimes this ic has only bad
contacts, resoldering is necessary.
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: NO PICTURE.(TU101)
Symptom: No picture.(led blinks 3X)
Cause: Tuner is defect, or the ground connection from
tuner is bad.
Remedy: Replace or resolder when necessary.
Model: AE2, AE2A, AE2B, KV-A2131A, KV-A2131B, ...
Subject: PICTURE IS TOO SMALL OR HORIZONTALY UNSTABEL.(C828)
Symptom: Picture is horizontaly unstabel, or picture is
to small.
Cause: C 828 is unstabel or value has changed.
Remedy: Change C 828
Model: AE2, KV-B2511A, KV-B2511B, KV-B2511D, KV-B2511K,
...
Subject: UNSTABEL PICTURE.(IC501)
Symptom: Unstabel picture.
Cause: On the microprocessorboard the TDA2595 is defect.
Remedy: Change this IC.
Model: AE2, KV-B2511A, KV-B2511B, KV-B2511D, KV-B2511K,
...
Subject: INTERMITTENT NO POWER.(IC1802)
Symptom: Intermittent no power.(led blinks 6X)
Cause: Only for sets equipped with a dynamic convergence
module (eq.KVS291*) CXA 1526 is defect.
Remedy: Change this IC and readjust convergence in the
service menu.
Model: AE2, KV-B2511A, KV-B2511B, KV-B2511D, KV-B2511K,
...
Subject: NO POWER.(IC091)
Symptom: No power (PSU is OK, no SCL,no SDA)
Cause: IR detector is defect. (SBX1610-11)
Remedy: Change IR detector
Model: AE2
Subject: FAILURE OF V-OUT IC
Symptom: FAILURE OF V-OUT IC
Cause: NO PICTURE DUE TO FAILURE OF THE V-OUT IC1501
(D-BOARD)
Remedy: REPLACE IC1501 TDA8179S BY STV9379
(8-759-192-71), AND CHANGE C1506 FROM 0,33 µF TO 0,10 µF
(1-130-777-00)
Model: AE2
Subject: VERTICAL PROTECTION TRIGGERED
Symptom: VERTICAL PROTECTION TRIGGERED
Cause: URING THE RECEPTION OF POOR-QUALITY SIGNALS (WEAK
SIGNALS, CROSS MODULATION, ETC. ),
VERTICAL DEFLECTION MAY STOP AFTER COVERING AROUND 60% OF
THE SCREEN. VERTICAL PROTECTION
THEN ACTIVATES AFTER W
Model: AE2
Subject: INCORRECT V-SIZE, DARK PICTURE, NO COLOUR,
SOUND B
Symptom: INCORRECT V-SIZE, DARK PICTURE, NO COLOUR,
SOUND BUZZ, ETC.
Cause: UE TO AC POWER ON/OFF SWITCHING, DISCHARGE,
ETC... DATA STORED IN THE NON VOLATILE
MEMORY (NVM) IC072 ON THE A-BOARD MAY CHANGE (TO ZERO ,
RESET). WHEN THE SYSTEM L IN
Model: AE2
Subject: OSD MALFUNCTIONING
Symptom: OSD MALFUNCTIONING
Cause: SD MALFUNCTIONING (FOR EXAMPLE : LETTERS OF OSD
MOVE ON THE SCREEN IN HORIZONTAL
DIRECTION). MALFUNCTION OF THE PLL CIRCUIT OF IC 04 (CXD
1050 A-15P) ON V-BOARD. (FAILURE IS
DEPENDING ON THE TEMPERATURE AND
Model: AE2
Subject: THE SET GIVES NO SOUND AFTER SOME TIME (THIS
TIME
Symptom: THE SET GIVES NO SOUND AFTER SOME TIME (THIS
TIME DEPENDS ON THE SIGNAL CONDITIONS
AND THE AUDIO LOAD). AFTER POWER-OFF AND POWER-ON THE SOUND
IS OK, UNTIL THE FAULT COMES
AGAIN.
Cause: HE PROBLEM IS CAUSED BY A BROKEN R627 (27 OHM 1/
Model: AE2
Subject: NO POWER, NO SOUND, FLASHING LED, ...
Symptom: NO POWER, NO SOUND, FLASHING LED, ...
Cause: M-BOARD COMES OUT OF FROM A-BOARD
Remedy: WHEN THE ABOVE MENTIONED SYMPTOM OCCURS, AT
FIRST CHECK IF THE M-BOARD CAME OUT. IN
THIS CASE , REFIT THE M-BOARD AND M-BOARD HOLDER AND BEND
THE
Model: AE2
Subject: MALFUNCTIONING OF PIP SYNCHRONISATION
Symptom: MALFUNCTIONING OF PIP SYNCHRONISATION
Cause: MALFUNCTIONING OF PIP SYNCHRONISATION
Remedy: CHECK THE PART NUMBER IMPRINTED ON THE A-BOARD.
IF THE PART NUMBER IS EITHER 1-642-994-
12 OR 1-642-994-21, THEN CHECK WETHER THERE IS A JUMP
Model: AE2
Subject: START UP PROBLEM
Symptom: START UP PROBLEM
Cause: NO START UP OR SLOW START UP (FLASHING LED). THE
400 MV REGULATION VOLTAGE WHICH IS
NECESSARY FOR START UP CANNOT BE REACHED AT PIN 1 OF IC601.
Remedy: REPLACE R611 (100 OHM) WITH A 120 OHM RESISTOR
(1-249-40
Model: AE2
Subject: NO PICTURE, NO SOUND, LED BLINKS 13 TIMES
Symptom: NO PICTURE, NO SOUND, LED BLINKS 13 TIMES
Cause: X RAY PROTECTION TRIGGERED DUE TO CHANGED VALUE
OF R866
Remedy: REPLACE R866
Model: AE2
Subject: INTERMITTENT PICTURE LOSS, LED BLINKS 13 TIMES
Symptom: INTERMITTENT PICTURE LOSS, LED BLINKS 13 TIMES
Cause: CRACKED SOLDERING ON IC1501 (V-OUT)
Remedy: RESOLDER IC1501
Model: AE2
Subject: TV OPERATES ONLY A FEW HOURS.
Symptom: TV OPERATES ONLY A FEW HOURS.
Cause: VALUE OF R610 CHANGED, Q601 DEFECT (OPEN)
Remedy: REPLACE R610 AND Q601
Model: AE2
Subject: INTERMITTENT SWITCH ON AND OFF.
Symptom: INTERMITTENT SWITCH ON AND OFF.
Cause: VALUE OF R612 CHANGED
Remedy: REPLACE R612
Model: AE2
Subject: No colour and menu and OSD are unstabel
Symptom: No colour and menu and OSD are unstabel
Cause: IC 681 gives wrong output voltages Normally 5V
and 12V
Remedy: Change IC 681 Part(s): 8-759-072-98 (IC 681)
Model: AE2
Subject: Set goes off after a while, or set start
blinking
Symptom: Set goes off after a while, or set start
blinking 13 times when you start the set.
Cause: Set has bad contacts on IC1501 or this IC1501 is
already defekt due to a bad contact.
Remedy: Change IC1501 and check his fusible resistors
R854 an
Model: AE2
Subject: TV doesn't start. +B is too high (170 V) Only
dem
Symptom: TV doesn't start. +B is too high (170 V) Only
demagnetisation is clicking.
Cause: PS601 is open due to bad contacts at IC 681
Remedy: Change PS601 and resolder IC681, R681. Part(s):
1-532-686-91 (PS 601)
Model: AE2
Subject: Plop-noise
Symptom: Plop-noise
Cause: One of the audio amplifiers is defekt.(TDA 2052)
Check also the value of R627 (27ohm)
Remedy: Change the audio amplifiers who are defekt and
change R 627 Part(s): 8-759-072-99 (IC 251 )
Model: AE2
Subject: Intermittenly no colour
Symptom: Intermittenly no colour
Cause: Bad contact FS057
Remedy: Resoldering FS057 Part(s): (FS057)
Model: AE2
Subject: TV doesn't start up. +B tension goes from 135V
to
Symptom: TV doesn't start up. +B tension goes from 135V
to 60V.(stand-by tension)
Cause: Q 281, Q 282 are defekt.(protection circuit
audio)
Remedy: Change Q281,Q282 Part(s): 8-729-120-28 (Q281)
8-729-120-28 (Q282
Model: AE2
Subject: Picture becomes reddish, bleuish or greenish
and b
Symptom: Picture becomes reddish, bleuish or greenish
and blanks.
Cause: The collectors of the RGB transistors (BF 871)
are touching because of dust or other cause.
Remedy: Reposition the 6 transistors and resolder them
correctly. Part(s): 8-729-
Model: AE2
Subject: No power
Symptom: No power
Cause: Q601, F651, IC601 are defekt, and even when they
are replaced the set goes directly defekt.
Remedy: Check R610 = 120K Part(s): 1-247-885-00 (R 610)
Model: AE2
Subject: Set goes in protection and blinks 8 times (AV
swit
Symptom: Set goes in protection and blinks 8 times (AV
switch)
Cause: Bad contact at IC 684 (9V stabilisator)
Remedy: Resoldering IC 684 Part(s): 8-759-982-10 (IC
684)
Model: AE2
Subject: No power
Symptom: No power
Cause: PS682 is open
Remedy: Change PS682 Part(s): 1-532-605-91 (PS 682)
Model: AE2
Subject: No power
Symptom: No power
Cause: R 612 is open
Remedy: Change R 612= 430Mohm Part(s): 1-247-894-11 (R
612)
Model: AE2
Subject: Set goes on and off and blanks 11X
Symptom: Set goes on and off and blanks 11X
Cause: IC01 is defekt (SDA5248CI)
Remedy: Change this IC Part(s): 8-759-073-28 (IC 01)
Model: AE2
Subject: After soldering the IC501 (vertical amplifier)
it
Symptom: After soldering the IC501 (vertical amplifier)
it is possible that image is still unstabel. 7 times blinking is possible
Cause: IC 561 is unstabel when warming up. (geometry
processor)
Remedy: Change IC 561 Part(s): 8-752-347-92 (IC 5
Model: AE2
Subject: Red, blue, green image with retrace lines in
the p
Symptom: Red, blue, green image with retrace lines in
the picture Al tensions arriving at the picture tube are OK
Cause: In most of the cases one of the 2SA1091 is
leaking.
Remedy: Change these 3 transistors Q 707, Q708, Q709
Part(s): 8-729-200-
Model: AE2
Subject: Plop noise
Symptom: Plop noise
Cause: TDA 6612 is defekt.
Remedy: Change this ic Part(s): 8-759-073-30 (IC 201)
Model: AE2
Subject: No NICAM sound
Symptom: No NICAM sound
Cause: IFB 101 is defekt due to a bad SIF signal.
Remedy: Change IFB 101 Part(s): 1-466-733-11 (IFB 389)
Model: AE2
Subject: The picture is green and yellow
Symptom: The picture is green and yellow
Cause: The electronic delay line is defekt.
Remedy: Change TDA 4660 Part(s): 8-759-505-39 (IC 302)
Model: AE2
Subject: Set gives different error codes (Led blinks 3
tim
Symptom: Set gives different error codes (Led blinks 3
times, afterwards 13 times)
Cause: Protection circuit is defekt ( Q611 and Q613) and
activates the X-ray protection
Remedy: Change these 2 transistors Part(s): 8-729-119-78
(Q611) 8-729-903-
Model: AE2
Subject: Bad focus in the middle of the screen
Symptom: Bad focus in the middle of the screen
Cause: LM 393 is defect.
Remedy: Change this ic. Part(s): 8-759-987-16 (IC1603)
Model: AE2
Subject: No power
Symptom: No power
Cause: Q801 is short, due to the +B tension = 190V.
Remedy: Check and change if neccesary IC603, D616,
IC602. Part(s): 8-749-923-44 (IC603) 8-719-110-31 (D 616) 8-759-
908-15 (IC602)
Model: AE2
Subject: Plop- noise
Symptom: Plop- noise
Cause: R 627 = open.
Remedy: Replace this resitor and check all audio
amplifiers. One of them should be defect. Part(s): 1-249-398-11 (R 627)
8-759-072-99 (IC 251,2
Model: AE2
Subject: Set goes in protection (intermittent.)
Symptom: Set goes in protection (intermittent.)
Cause: Q 611 or Q 611 are leaking.
Remedy: Change both transistors. Part(s): 8-729-216-22
(Q610) 8-729-119-78 (Q611
Model: AE2
Subject: No power(cycling power on/off.)
Symptom: No power(cycling power on/off.)
Cause: PS601 is open.
Remedy: Replace this fuse. Part(s): 1-532-686-91 (PS601)
Model: AE2
Subject: Sync problem
Symptom: Sync problem
Cause: IC 681 is defect.
Remedy: Change this ic Part(s): 8-759-072-98 (IC 681)
Model: AE2
Subject: No picture.(led blinks 3X)
Symptom: No picture.(led blinks 3X)
Cause: Tuner is defect, or the ground connection from
tuner is bad.
Remedy: Replace or resolder when necessary. Part(s):
1-693-185-11 (TU 101)
Model: AE2
Subject: Picture is horizontaly unstabel, or picture is
to
Symptom: Picture is horizontaly unstabel, or picture is
to small.
Cause: C 828 is unstabel or value has changed.
Remedy: Change C 828 Part(s): 1-137-041-91 (C 828)
Model: AE2
Subject: Unstabel picture.
Symptom: Unstabel picture.
Cause: On the microprocessorboard the TDA2595 is defect.
Remedy: Change this IC. Part(s): 8-759-513-48 (IC 501)
Model: AE2
Subject: Intermittent no power.(led blinks 6X)
Symptom: Intermittent no power.(led blinks 6X)
Cause: Only for sets equipped with a dynamic convergence
module (eq.KVS291*) CXA 1526 is defect.
Remedy: Change this IC and readjust convergence in the
service menu. Part(s): 8-752-052-88 (IC1802)
Model: AE2
Subject: No power (PSU is OK, no SCL,no SDA)
Symptom: No power (PSU is OK, no SCL,no SDA)
Cause: IR detector is defect. (SBX1610-11)
Remedy: Change IR detector Part(s): 8-741-101-75 (IC091)
Model: AE2
Subject: No power
Symptom: No power
Cause: Lightening
Remedy: Check the following componentSymptom
:D606,D604(if used), IC603,D616,IC602, PS601,D610, Q613(if
used),Q601, IC601,Q801. Check also that circuit board itself
is not damaged! Part(s): ()
Model: AE2A, AE2B, KV-A2131A, KV-A2131B, KV-A2131D, ...
Subject: SET IS IN PROTECTION.(IC2002)
Symptom: Set goes in protection.(no errorcode)
Cause: IC2002 on the M1 or M2 board is defect.(IC2002 is
TXT-IC)
Remedy: Change IC2002.
Model: AE2A
Subject: FAILURE OF V-OUT IC
Symptom: FAILURE OF V-OUT IC
Cause: NO PICTURE DUE TO FAILURE OF THE V-OUT IC1501
(D-BOARD)
Remedy: REPLACE IC1501 TDA8179S BY STV9379
(8-759-192-71), AND CHANGE C1506 FROM 0,33 µF TO 0,10 µF
(1-130-777-00)
Model: AE2A
Subject: VERTICAL PROTECTION TRIGGERED
Symptom: VERTICAL PROTECTION TRIGGERED
Cause: URING THE RECEPTION OF POOR-QUALITY SIGNALS (WEAK
SIGNALS, CROSS MODULATION, ETC. ),
VERTICAL DEFLECTION MAY STOP AFTER COVERING AROUND 60% OF
THE SCREEN. VERTICAL PROTECTION
THEN ACTIVATES AFTER W
Model: AE2A
Subject: THE SET GIVES NO SOUND AFTER SOME TIME (THIS
TIME
Symptom: THE SET GIVES NO SOUND AFTER SOME TIME (THIS
TIME DEPENDS ON THE SIGNAL CONDITIONS
AND THE AUDIO LOAD). AFTER POWER-OFF AND POWER-ON THE SOUND
IS OK, UNTIL THE FAULT COMES
AGAIN.
Cause: HE PROBLEM IS CAUSED BY A BROKEN R627 (27 OHM 1/
Model: AE2A
Subject: START UP PROBLEM
Symptom: START UP PROBLEM
Cause: NO START UP OR SLOW START UP (FLASHING LED). THE
400 MV REGULATION VOLTAGE WHICH IS
NECESSARY FOR START UP CANNOT BE REACHED AT PIN 1 OF IC601.
Remedy: REPLACE R611 (100 OHM) WITH A 150 OHM RESISTOR
(1-249-40
Model: AE2A
Subject: Set goes in protection.(no errorcode)
Symptom: Set goes in protection.(no errorcode)
Cause: IC2002 on the M1 or M2 board is defect.(IC2002 is
TXT-IC)
Remedy: Change IC2002. Part(s): 8-759-181-21 (IC2002)
Model: AE2B
Subject: INTERMITTENT SWITCH ON AND OFF. LED BLINKS 13
TIME
Symptom: INTERMITTENT SWITCH ON AND OFF. LED BLINKS 13
TIMES.
Cause: VALUE OF R818 CHANGED. X-RAY PROTECTION SWITCHES
ON.
Remedy: REPLACE R818
Model: AE2B
Subject: NO OPERATION OR JUST SWITCH ON AND THEN SWITCH
OFF
Symptom: NO OPERATION OR JUST SWITCH ON AND THEN SWITCH
OFF.
Cause: R634 DEFECT
Remedy: REPLACE R634
Model: AE2B
Subject: NO PICTURE, NO SOUND, OSD CHARACTERS HARDLY
APPEAR
Symptom: NO PICTURE, NO SOUND, OSD CHARACTERS HARDLY
APPEAR. LED A BLINKS SLOWLY.
Cause: TUNER TU101 DEFECT.
Remedy: REPLACE TUNER TU101
Model: AE2B
Subject: PICTURE SIZE IS REDUCED AT SWITCHED ON.
Symptom: PICTURE SIZE IS REDUCED AT SWITCHED ON.
Cause: INCORRECT VOLTAGE FROM IC681 (5V / 12V REGULATOR)
DUE TO OVERLOAD CAUSED BY IC202
(HEADPHONES AMPLIFIER).
Remedy: REPLACE IC202 (TDA2822)
Model: AE2F, KV-E2561A, KV-E2561D, KV-E2561K, KV-E2563B,
...
Subject: NO PIP.(IC1401)
Symptom: No PIP
Cause: IC1401 is defect.(SCP at pin 6 is not correct)
Remedy: Change this IC. Check also SB TV02695.
Model: AE2F, KV-E2561A, KV-E2561D, KV-E2561K, KV-E2563B,
...
Subject: UNSTABEL PICTURE.(IC6)
Symptom: Unstabel picture
Cause: IC6 from Q board is defect.
Remedy: Change this IC.
Model: AE2F, KV-E2561A, KV-E2561D, KV-E2561K, KV-E2563B,
...
Subject: DARK PICTURE.(RGB)
Symptom: Dark picture
Cause: One or more RGB IC's on the C bord are defect.
Remedy: Change this IC and check also the other
semi-conductors.
Model: AE2F, KV-E2561A, KV-E2561D, KV-E2561K, KV-E2563B,
...
Subject: SET GOES OFF AFTER A WHILE.(R848)
Symptom: Set goes off after a while.
Cause: R 848 is open.
Remedy: Change R 848. When R 848 is open, Q 805 conducts
and also Q 806 and hence the protection is activated.
Model: AE2F, KV-E2561A, KV-E2561D, KV-E2561K, KV-E2563B,
...
Subject: NORD-SOUTH ERROR.(Q1856,PS1852)
Symptom: N/S fault
Cause: Q1856 on the D2 board is short and hence PS1852
is also defect.
Remedy: Change both components and resolder also the
other semi-conductors on this D2 board.
Model: AE2F, KV-E2561A, KV-E2561D, KV-E2561K, KV-E2563B,
...
Subject: WHITE FLASHES IN THE PICTURE, CYCLIC
ON/OFF.(IC072)
Symptom: Cyclic power ON/OFF and picture flashes.
Cause: Memory IC is defect.
Remedy: Change IC072 and reload the corresponding data
by using our PC-based TV repair assistance tool: TRACE.
Model: AE2F, KV-E2561A, KV-E2561D, KV-E2561K, KV-E2563B,
...
Subject: PIN CUSHION PROBLEM.(D819)
Symptom: Picture has a pin-cushion problem.
Cause: D 819 is defect.
Remedy: Change this diode.
Model: AE2F, KV-E2561A, KV-E2561D, KV-E2561K, KV-E2563B,
...
Subject: SET SWITCHES OFF AND BLINKS 13 X.
Symptom: Set goes off and blinks 13 times.
Cause: 1)STV9379 is defect or has bad contacts. 2)Check
TDA2579B on the B board.
Remedy: 1)Change or resolder this STV9379. 2)Change this
TDA2579B.
Model: AE2F, KV-E2561A, KV-E2561D, KV-E2561K, KV-E2563B,
...
Subject: NO PICTURE.(R741,R743)
Symptom: No Picture
Cause: G2 tension is to low.
Remedy: Check R743 and R741 (820K) and replace when
their value has changed.
Model: AE2F
Subject: No picture, no synchronisation, no operation
Symptom: No picture, no synchronisation, no operation
Cause: IC6 and/or IC7 on Q board defect
Remedy: Replace IC6 or IC7 on Q board
Model: AE2F
Subject: Stripes in the picture, no picture, .
Symptom: Stripes in the picture, no picture, .
Cause: Field memories IC2 and IC3 on Q board defect.
Remedy: Replace IC2 and IC3 on Q board
Model: AE2F
Subject: No PIP
Symptom: No PIP
Cause: IC1401 is defect.(SCP at pin 6 is not correct)
Remedy: Change this IC. Part(s): 8-759-183-35 (IC1401)
Model: AE2F
Subject: Unstabel picture
Symptom: Unstabel picture
Cause: IC6 from Q board is defect.
Remedy: Change this IC. Part(s): 8-759-257-92 (IC6)
Model: AE2F
Subject: Dark picture
Symptom: Dark picture
Cause: One or more RGB IC's on the C bord are defect.
Remedy: Change this IC and check also the other
semi-conductors. Part(s): 8-759-073-90 (IC ...)
Model: AE2F
Subject: Set goes off after a while.
Symptom: Set goes off after a while.
Cause: R 848 is open.
Remedy: Change R 848. Part(s): 1-215-477-00 (R 848)
Model: AE2F
Subject: N/S fault
Symptom: N/S fault
Cause: Q1856 on the D2 board is short and hence PS1852
is also defect.
Remedy: Change both components and resolder also the
other semi-conductors on this D2 board. Part(s): 8-729-017-05
(Q1856)
Model: AE2F
Subject: Cyclic power ON/OFF and picture flashes.
Symptom: Cyclic power ON/OFF and picture flashes.
Cause: Memory IC is defect.
Remedy: Change IC072 and reload the corresponding data
by using our PC-based TV repair assistance tool: TRACE.
Part(s): 8-759-184-27 (IC 072)
Model: AE2F
Subject: Picture has a pin-cushion problem.
Symptom: Picture has a pin-cushion problem.
Cause: D 819 is defect.
Remedy: Change this diode. Part(s): 8-719-914-43 (D 819)
Model: AE2F
Subject: Bad colours(horizontal coloured stripes)
Symptom: Bad colours(horizontal coloured stripes)
Cause: Data loss.
Remedy: Change in the service menu under ECO 3 nr 11 =
ON. Part(s): ()
Model: AE2F
Subject: Set goes off and blinks 13 times.
Symptom: Set goes off and blinks 13 times.
Cause: 1)STV9379 is defect or has bad contacts. 2)Check
TDA2579B on the B board.
Remedy: 1)Change or resolder this STV9379. 2)Change this
TDA2579B. Part(s): 8-759-192-71 (IC1501) 8-759-181-19
(IC501
Model: AE2F
Subject: No Picture
Symptom: No Picture
Cause: G2 tension is to low.
Remedy: Check R743 and R741 (820K) and replace when
their value has changed. Part(s): 1-202-884-11 (R741 ) 1-202-
881-11 (R743)