Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject: NO
POWER.(D502,D503)
Symptom: No
power
Cause: D502
and D503 are short (damper diodes)
Remedy:
Change these components. Even after replacing these components, there is
still no pin correction Check PS1502 (not
mentioned on the D1 board) and change this fusable resistor
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
PICTURE IS OUT OF SYNC.(IC3502)
Symptom:
Picture is out of sync.
Cause: IC
3502 is defect.(B board)
Remedy:
Change IC 3502(TDA 9144/N1)
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
UNSTABEL AUDIO.(IC201)
Symptom:
Unstabel audio
Cause: IC
201 (MSP3410D-PS-B4-T) is defect.
Remedy:
Change this IC.
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject: NO
VERTICAL SYNCHRO.(IC317)
Symptom: No
vertical synchro.
Cause: IC
317 is defect.(soft 100Hz processing)
Remedy:
Change this IC.
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
INTERMITTENT NO SWITCH ON, NO I.R. RECEPTION, UNST
Symptom:
Intermittent no I.R reception, unstabel picture,...
Cause: Bad
contacts at IC 1136 and IC 1137.
Remedy: Add
flux and resolder both IC's. Clean up board in this area with a product used
for this purpose. Check main functions
of the set a
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
CLOCK IS NOT WORKING.(IC1141)
Symptom:
Clock doesn't work.
Cause: IC
1141 is defect.
Remedy:
Change IC 1141 (PCF8593/T3)
Model: GE1
Subject:
UNCORRECT H-SIZE AND PIN DEFORMATION.(D503)
Symptom:
Uncorrect H size and pin deformation.
Cause: D
503 is short.
Remedy:
Change this diode.
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
POWERS UP BUT NO OPERATION.(IC1510)
Symptom:
Powers up, but no operation.
Cause: IC
1510 is defect.(IR2112)
Remedy:
Change this IC.
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
INTERMITTENT VERTICAL NOISE BAR IN THE PICTURE.(D6
Symptom:
Intermittent vertical noisebar in picture.
Cause: Bad
contacts D 602.
Remedy:
Resolder D 602. Readjust mounting of D 602 when necessary.
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject: NO
POWER.(IC1116)
Symptom: No
power.
Cause:
Microprocessor is defect.
Remedy:
Change IC 1116. Normally power supply stand-by tensions are present(Stand-by
5V,11V,35V) AC ON/OFF tension on
pin 31 from the microprocessor is too low.(1V i.p.v 5V)
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
SET POWERS UP, FALLS INTO STAND-BY AND BLINKS 4X.(
Symptom:
Set powers up,falls in stand-by and blinks 4X.
Cause: IC
502 is defect.(vertical amplifier)
Remedy:
Change this IC and check the fusable resistors R519 and R518.
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
PIN CUSHION PROBLEM.(PS1502)
Symptom:
Pin-cushion problem.
Cause: PS
1502 is open.
Remedy:
Change this fusable resistor. PS 1502 is not mentioned in the service manuel!!!!!
Check also the damper diodes!
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject: NO
POWER.(LIGHTENING)
Symptom: No
power,lightening.
Cause:
Lightening!
Remedy:
Check Q 604, D 633, D 600, Q 609 and IC 1116,(microprocessor) and replace
when necessary. Check correct partnumbers
in the SM or ASSIST.
Model: GE1
Subject: No
power
Symptom: No
power
Cause: D502
and D503 are short(damper diodes)
Remedy:
Change these components. Part(s): 8-719-979-99 (D502) 8-719-052-09 (D503)
1-532-637-00 (PS1502)
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject: NO
POWER.(D502,D503)
Symptom: No
power
Cause: D502
and D503 are short(damper diodes)
Remedy:
Change these components. Even after replacing these components, there is
still no pin correction Check PS1502 (not
mentioned on the D1 board) and change this fusable resistor
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
PICTURE IS OUT OF SYNC.(IC3502)
Symptom:
Picture is out of sync.
Cause: IC
3502 is defect.(B board)
Remedy:
Change IC 3502(TDA 9144/N1)
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
UNSTABEL AUDIO.(IC201)
Symptom:
Unstabel audio
Cause: IC
201 (MSP3410D-PS-B4-T) is defect.
Remedy:
Change this IC.
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject: NO
VERTICAL SYNCHRO.(IC317)
Symptom: No
vertical synchro.
Cause: IC
317 is defect.(soft 100Hz processing)
Remedy:
Change this IC.
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
INTERMITTENT NO SWITCH ON, NO I.R. RECEPTION, UNST
Symptom:
Intermittent no I.R reception, unstabel picture,...
Cause: Bad
contacts at IC 1136 and IC 1137.
Remedy: Add
flux and resolder both IC's. Clean up board in this area with a product used
for this purpose. Check main functions
of the set a
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
CLOCK IS NOT WORKING.(IC1141)
Symptom:
Clock doesn't work.
Cause: IC
1141 is defect.
Remedy:
Change IC 1141 (PCF8593/T3)
Model: GE1
Subject:
UNCORRECT H-SIZE AND PIN DEFORMATION.(D503)
Symptom:
Uncorrect H size and pin deformation.
Cause: D
503 is short.
Remedy:
Change this diode.
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
POWERS UP BUT NO OPERATION.(IC1510)
Symptom:
Powers up, but no operation.
Cause: IC
1510 is defect.(IR2112)
Remedy:
Change this IC.
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
INTERMITTENT VERTICAL NOISE BAR IN THE PICTURE.(D6
Symptom:
Intermittent vertical noisebar in picture.
Cause: Bad
contacts D 602.
Remedy:
Resolder D 602. Readjust mounting of D 602 when necessary.
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject: NO
POWER.(IC1116)
Symptom: No
power.
Cause:
Microprocessor is defect.
Remedy:
Change IC 1116. Normally power supply stand-by tensions are present(Stand-by
5V,11V,35V) AC ON/OFF tension on
pin 31 from the microprocessor is too low.(1V i.p.v 5V)
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
SET POWERS UP, FALLS INTO STAND-BY AND BLINKS 4X.(
Symptom:
Set powers up,falls in stand-by and blinks 4X.
Cause: IC
502 is defect.(vertical amplifier)
Remedy:
Change this IC and check the fusable resistors R519 and R518.
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject:
PIN CUSHION PROBLEM.(PS1502)
Symptom:
Pin-cushion problem.
Cause: PS
1502 is open.
Remedy:
Change this fusable resistor. PS 1502 is not mentioned in the service manuel!!!!!
Check also the damper diodes!
Model: GE1,
KV-28FD1E, KV-28FD1K, KV-32FD1E, KV-32FD1K
Subject: NO
POWER.(LIGHTENING)
Symptom: No
power,lightening.
Cause:
Lightening!
Remedy:
Check Q 604, D 633, D 600, Q 609 and IC 1116,(microprocessor) and replace
when necessary. Check correct partnumbers
in the SM or ASSIST.
Model: GE1
Subject: No
power
Symptom: No
power
Cause: D502
and D503 are short(damper diodes)
Remedy:
Change these components. Part(s): 8-719-979-99 (D502) 8-719-052-09 (D503)
1-532-637-00 (PS1502)